Technical data — electrical ratings | |
---|---|
Voltage supply | 9…30 VDC 5 VDC ±5 % 9…26 VDC |
Consumption w/o load | 100 mA |
Pulses per revolution | 25…5000 |
Phase shift | 90° ±20° |
Scan ratio | 40…60 % |
Reference signal | Zero pulse, width 90° |
Sensing method | Optical |
Output frequency | 120 kHz (pulses 1250) 250 kHz (pulses >1250) |
Output signals | K1, K2, K0 + inverted |
Output stages | HTL TTL/RS422 |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-3 |
Approval | CE |
Technical data — mechanical design | |
Size (flange) | 115 mm |
Shaft type | 11 mm solid shaft |
Shaft loading | 200 N axial 350 N radial |
Flange | EURO flange B10 |
Protection DIN EN 60529 | IP 56 |
Operating speed | 6000 rpm (T5, mechanical) 4500 rpm (T6, mechanical) |
Operating torque typ. | 4 Ncm |
Rotor moment of inertia | 290 gcm |
Materials | Housing: aluminium die-cast Shaft: stainless steel |
Ambient temperature | -20…+55 °C |
Resistance | IEC 60068-2-6 Vibration 10 g, 50-2000 Hz IEC 60068-2-27 Shock 100 g, 6 ms |
Explosion protection | II 2 G Ex d e IIC T5/T6 Gb Ex d e IIC T5/T6 Gb |
Connection | Terminal box |
Weight approx. | 3.5 kg |