Technical data — electrical ratings | |
---|---|
Voltage supply | 9…30 VDC 5 VDC ±5 % 9…26 VDC |
Consumption w/o load | 100 mA |
Pulses per revolution | 250…2500 |
Phase shift | 90° ±20° |
Scan ratio | 40…60 % |
Reference signal | Zero pulse, width 90° |
Sensing method | Optical |
Output frequency | 120 kHz |
Output signals | K1, K2, K0 + inverted |
Output stages | HTL TTL/RS422 |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-3 |
Approval | CE |
Technical data — mechanical design | |
Size (flange) | 160 mm |
Shaft type | 30…70 mm (through hollow shaft) |
Shaft loading | 450 N axial 650 N radial |
Protection DIN EN 60529 | IP 54 IP 56 |
Operating speed | 5600 rpm (mechanical) |
Operating torque typ. | 60 Ncm |
Rotor moment of inertia | 31.9 kgcm ( 40) 11.3 kgcm ( 70) |
Materials | Housing: aluminium alloy Shaft: stainless steel |
Ambient temperature | -20…+58 °C (IP 56) -20…+66 °C (IP 54) |
Resistance | IEC 60068-2-6 Vibration 10 g, 50-2000 Hz IEC 60068-2-27 Shock 100 g, 6 ms |
Explosion protection | II 2 G Ex d e IIC T6 Gb Ex d e IIC T6 Gb |
Connection | Terminal box |
Weight approx. | 8.8 kg ( 40) 6.2 kg ( 70) |