Technical data — electrical ratings
Voltage supply 8…30 VDC
Reverse polarity protection Yes
Short-circuit proof Yes
Consumption typ. 35 mA (24 VDC, w/o load)
Initializing time 500 ms after power on
Response time  
Interface analog 0…10 V / 0.5…4.5 V / 4…20 mA
Resolution: 12 bit
Function Multiturn
Steps per turn 4096 / 12 bit
Number of turns 65536 / 16 bit
Absolute accuracy ±1 °
Sensing method Magnetic
Linearity 0.06 % of measuring range (10 revolutions)
0.17 % of measuring range (2 revolutions)
0.31 % of measuring range (360°)
0.6 % of measuring range (90°)
Repeatability 0.3 ° (Sensorsystem)
Code sequence CW: ascending values with clockwise sense of rotation; looking at flange
Interference immunity DIN EN 61000-6-2
Emitted interference DIN EN 61000-6-4
Programmable
parameters
Measuring range teachable, min. 10°
Diagnostic functions Self-diagnosis
Reading back voltage output
Factory setting 10 revolutions
Technical data — mechanical design
Size (flange) 58 mm
Shaft type 6 mm solid shaft
Flange Synchro flange
Protection DIN EN 60529 IP 65
Operating speed 12000 rpm (mechanical)
6000 rpm (electric)
Operating torque typ. 0.0023 Nm
Shaft loading 10 N axial
20 N radial
Materials Housing: aluminium
Flange: aluminium
Operating temperature -40…+85 °C
Relative humidity 95 %
Resistance DIN EN 60068-2-6
Vibration 30 g, 10-2000 Hz
DIN EN 60068-2-27
Shock 500 g, 6 ms
Weight approx. 300 g
Connection Connector M12, 5-pin
Connector M12, 8-pin
Cable 2 m